Produktai skirti slidinėjimo 2023 m (7)

Lubų gaisro sklendė EI 60 - gaisro spąstai

Lubų gaisro sklendė EI 60 - gaisro spąstai

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboard Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018EN 1634-1: +A1: 2018 Fire dampers EI 60 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.
Vaikų Megztas Kalėdų Šalmas 2vnt - ŠALMAI IR KEPURĖS

Vaikų Megztas Kalėdų Šalmas 2vnt - ŠALMAI IR KEPURĖS

Mettez en valeur ce beau bonnet en tricot sur vos marchés de Noël pour attirer les enfants ! Les parents sont ravis de leur faire plaisir en leur achetant ce petit présent. Vous boostez vos ventes en un instant ! Référence:NEDZ1125 EAN13:3700299941370
300BEL Rankinė Vertikali Pjūklas su Sulankstomu Rėmu - Pjūklai Panelems

300BEL Rankinė Vertikali Pjūklas su Sulankstomu Rėmu - Pjūklai Panelems

Châssis monobloc en acier mécano-soudé Moteur 7,5 CV tri 400 V à frein électromagnétique Circuit de commande basse tension 24 V Lame carbure 300/30 mm Vitesse de rotation de lame 4500 tr/mn Profondeur de coupe maximum 80 mm Escamotage manuel des lattes supports de panneaux Rouleaux de transport escamotables Rail rabattable intermédiaire 3000 mm Butée de coupe répétitive 650 mm 5 butées de programmation de coupe horizontale Sortie sciures latérale ø 100 mm 5 formats de coupe 300BEL 3116 : 3100 x 1600 300BEL 3119 : 3100 X 1900 300BEL 4121 : 4100 x 2100 300BEL 5022 : 5000 x 2200 300BEL 7022 : 7000 x 2200 Plan d’appui escamotable automatique électrique Système de récupération optimisée des sciures de coupes horizontales et rail rabattable intermédiaire sur toute longueur Rail rabattable intermédiaire 3750 mm Rail rabattable intermédiaire 4500 mm Moteur frein 5,5 CV 2 vitesse Variateur de vitesse électronique
Nešiojamos Gręžimo Mašinos - Mūsų Partneris ELSA - Gręžimo Mašinos

Nešiojamos Gręžimo Mašinos - Mūsų Partneris ELSA - Gręžimo Mašinos

Pour accéder au site ELSA, cliquez ci- après
Sublim'Air

Sublim'Air

Son agent exclusif permet d’éliminer les odeurs à la source par action moléculaire. Les mauvaises odeurs sont définitivement éliminées.
Lubų gaisro spąstai 120 MN - gaisro spąstai

Lubų gaisro spąstai 120 MN - gaisro spąstai

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018 Fire dampers EI 120 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 120. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.
Lubų gaisro spąstai 60 MIN - gaisro spąstai

Lubų gaisro spąstai 60 MIN - gaisro spąstai

Frame made of aluminium profile bars connected by "Tox" connections - Intumescent gas, smoke and flame tight seal in case of fire - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards - Quick and easy installation The 60-minute ceiling fire dampers are designed for installation in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60. They provide effective protection against fire progression from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms. The safety catching arms ensure that the lid is intercepted every time the hatch is opened. The lid is easy to remove and replace.