Produktai skirti 100 (4)

Lengvai montuojamos diferencialinio slėgio įrenginiai ISO 100/120 - ISO 120

Lengvai montuojamos diferencialinio slėgio įrenginiai ISO 100/120 - ISO 120

Isolation Unit, 1-piece, for positive or negative room pressure This Isolation Unit is made for installation in suspended or false ceilings, and walls. Can be connected to an existing ventilation system or new tube system. Reccommended for installations were the point of extraction and supply are further away from eachother. Depending on the installation, positive (for immune-compromised) or negative (for infectious patients) pressure is generated inside the room (easily up to 20 Pascal). Filters used in this Isolation Unit are of HEPA14 or ULPA15 quality, leaktested and airtight secured. – Automatic differential pressure regulation – Automatic pressure loss alert – Filter detection by ID code (filter condition) – Complies with CDC guidelines (Centres for Disease Control and Prevention) Used in hospitals, clinics and medical facilities Immune-compromised patients Oncology, haematology, neonato
Nuotoliniai valdikliai RC 100 izoliacijos įrenginiui - Nuotoliniai valdikliai RC 100 visiems MedicCleanAir įrenginiams

Nuotoliniai valdikliai RC 100 izoliacijos įrenginiui - Nuotoliniai valdikliai RC 100 visiems MedicCleanAir įrenginiams

Remote controllers with key switches or with key switches and screen-displays for permanent 100 % security, used with all MedicCleanAir units. Remote controller RC 100 with key switches Key switch to select speed. Connects directly to the air purification unit or isolation unit / no seperate power supply needed. Avoids undesirable external use (only hospital staff)
Oro atgalinio slėgio sklendė - Oro atgalinio slėgio sklendė diferencinio slėgio įrenginiui ISO 100/120

Oro atgalinio slėgio sklendė - Oro atgalinio slėgio sklendė diferencinio slėgio įrenginiui ISO 100/120

Isolation Unit, 1-piece, for positive or negative room pressure This Isolation Unit is made for installation in suspended or false ceilings, and walls. Can be connected to an existing ventilation system or new tube system. Reccommended for installations were the point of extraction and supply are further away from eachother. Depending on the installation, positive (for immune-compromised) or negative (for infectious patients) pressure is generated inside the room (easily up to 20 Pascal). Filters used in this Isolation Unit are of HEPA14 or ULPA15 quality, leaktested and airtight secured. – Automatic differential pressure regulation – Automatic pressure loss alert – Filter detection by ID code (filter condition) – Complies with CDC guidelines (Centres for Disease Control and Prevention) Used in hospitals, clinics and medical facilities Immune-compromised patients Oncology, haematology, neonato